DESCRIPTION
Adjustable alarm limits / Robust housing / Software / Data storage /
High accuracy of up to ±(1.0% of reading + 0.5 µm) / Optionally with ISO calibration certificate
During the measurements, the measured values can be saved on the coating thickness gauge. A memory of a maximum of 2,000 measured values is available for the coating thickness gauge. After a measurement run, the measured values from the coating thickness gauge can be transferred to a computer and analyzed using the software. For further processing of the measured values, they can be exported in CSV format.
A target/actual range can be stored with the limit value alarm function on the coating thickness gauge. If the test object is within the stored area at the coating thickness gauge, this is signaled by a green LED. If the measured value is outside the set range, this is indicated by a red LED from the coating thickness gauge. Because of the limit value alarm function, the coating thickness gauge is used, for example, in incoming and final inspection for quality assurance.
For a special protection of the electronics, the housing of the coating thickness gauge is additionally rubberized. Optionally, the coating thickness gauge can be equipped with an ISO calibration certificate.
HIGHLIGHTS
– High accuracy for small coatings
– Adjustable limit values
– Data memory for 2000 readings
– Measuring range of up to 0 … 5000 µm
– Optionally with ISO calibration certificate
SPECIFICATION
Measuring range | Fe: 0 … 5000 µm, NFe: 0 … 3000 µm |
Accuracy after foil calibration | ±(1.5 % of measured value + 1 µm) |
Accuracy after zeroing | ±(1.75 % of measured value + 1 µm) |
Probe diameter | Ø17 mm / 0.67″ |
Resolution | 0.1 µm (<100 µm), 1 µm (>100 µm) |
Measurable materials | |
Fe substrates such as: | Fe substrates such as: steel and iron |
NFe substrates such as: | NFe substrates such as: aluminum and copper |
Min. radius of curvature convex | 5 mm / 0.19″ |
Min. radius of curvature concave | 25 mm / 0.98″ |
Min. measuring surface | Ø17 mm / 0.67″ |
Min. layer thickness | 0.2 mm / 0.007″ (on magnetic materials) |
0.05 mm / 0.002″ (on non-magnetic materials) | |
Probe mode | Auto material detection mode (Fe + NFe) |
Magnet mode (Fe) | |
Eddy current mode (NFe) | |
Calibration | Multi-point calibration |
(1 … 4 points for each group) | |
Zero calibration | |
Units | µm, mm, mils |
Data transfer | USB 2.0 |
Memory | A volatile measurement group (DIR mode) |
Four measurement groups with autom. | |
storage and max. 2000 readings (GEN mode) | |
Statistics functions | Number of measured values, mean, |
minimum, maximum, standard deviation | |
Alarm | Display when the adjustable value is exceeded |
upper and lower alarm limit | |
Automatic shutdown | auto. shutdown mode (3 min.) |
Power supply | 3 x 1.5 V AAA batteries |
Display | 128 x 128 px LCD display |
Additional displays | battery status, error detection |
Operating conditions | 0 … +50 °C / 32 … 122 °F |
20 … 90 % RH non-condensing | |
Storage conditions | -10 … +60 °C / 14 … 140 °F |
20 … 90 % RH non-condensing | |
Dimensions | 143 x 71 x 37 mm / 5.6 x 2.8 x 1.4″ (L x W x H) |
Weight | with sensor and batteries: 271 g / 9.5 oz |
DELIVERY SCOPE
1 x Sensor
3 x 1.5V AAA batteries
1 x Carrying case
1 x Set of standard foils
1 x Calibration plates (Fe and NFe)
1 x Instruction manual
There are no reviews yet.