SpecificationsMaximum voltage between any terminal and earth ground600 VSurge protection6 kV peak per IEC 61010–1 600 VCAT III, Pollution Degree 2Fuse for A input11 A, 1000 V FAST Fuse (Fluke PN 803293)DisplayDigital: 6,000 counts, updates 4 per secondBar graph33 segments, updates 32 per secondOperating temperature-10°C to +50°CStorage temperature-40°C to +60°CBattery type9 volt Alkaline, NEDA 1604A / IEC 6LR61Battery life400 hours typical, without backlightAccuracy SpecificationsDC millivoltsRange/resolution600.0 mV / 0.1 mVAccuracy±([% of reading] + [counts]): 0.5% + 2DC voltsRange/resolution6.000 V / 0.001 V
60.00 V / 0.01 V
600.00 V / 0.1 VAccuracy±([% of reading] + [counts]): 0.5% + 2Auto voltsRange/resolution600.0 V / 0.1 VAccuracy2.0% + 3 (DC, 45 Hz to 500 Hz)
4.0% + 3 (500 Hz to 1 kHz)AC millivolts¹ True RMSRange/resolution600.0 mV / 0.1 mVAccuracy1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)AC volts¹ True RMSRange/resolution6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 VAccuracy1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)ContinuityRange/resolution600 Ω / 1 ΩAccuracyBeeper on < 20 Ω, off > 250 Ω detects opens or shorts of
500 μs or longer.OhmsRange/resolution600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
600.0 kΩ / 0.1 kΩ
6.000 MΩ / 0.001 MΩAccuracy0.9% + 1Range/resolution40.00 MΩ / 0.01 MΩAccuracy5% + 2Diode testRange/resolution2.00 V / 0.001 VAccuracy0.9% + 2CapacitanceRange/resolution1000 nF / 1 nF
10.00 μF / 0.01 μF
100.0 μF / 0.1 μF
9999 μF / 1 μF
100 μF to 1000 μFAccuracy1.9% + 2Range/resolution> 1000 μFAccuracy5% + 20%Lo-Z capacitanceRange1 nF to 500 μFAccuracy10% + 2 typicalAC amps True RMS (45 Hz to 500 Hz)Range/resolution6.000 A / 0.001 A
10.00 A / 0.01 AAccuracy1.5% + 3
20 A continuous overload for 30 seconds maxDC ampsRange/resolution6.000 A / 0.001 A 10.00 A / 0.01 AAccuracy1.0% + 3
20 A continuous overload for 30 seconds maxHz (V or A input)²Range/resolution99.99 Hz / 0.01 Hz
999.99 Hz / 0.1 Hz
9.999 Hz / 0.001 Hz
50.00 Hz / 0.01 HzAccuracy0.1% + 21. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.
2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
2. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.
2. Temperature Range/Resolution: -40°F to 752°F / 0.2°F.Mechanical and General SpecificationsSize167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)Weight550 gWarranty3 years
FLUKE 117 TRUE RMS ELECTRICAL MULTIMETER WITH NON-CONTACT VOLTAGE
# 117
- Electrician’s Multimeter with Non-Contact Voltage Detector (TRMS; 600VAC/DC; Ohms; Continuity)
- Ideal multimeter for all professional electricians
- Measures AC/DC voltage; current; resistance; continuity; frequency and capacitance