DESCRIPTION
Export of the saved measurement data in CSV format / Battery and mains operation /
1/4 inch tripod mount / Measuring range (CO²) 0 … 9999 ppm, (CO) 0 … 1000 ppm
During the measurement, the readings are stored on the data logger. Up to 5000 measuring points can be saved on the air quality detector. The CO² and CO content, as well as the temperature and humidity are saved by the air quality detector for each storage point. After a measurement run, the stored measurement values can be viewed directly on the air quality detector.
For further processing, the readings recorded by the data logger can be transferred to a computer. The transfer takes place via the Micro-USB interface of the air quality detector. When connecting the CO and CO² meter to a computer, it is recognized as a mass data storage device. The saved measured values are saved by the air quality detector in CSV file format and can therefore be processed directly.
The built-in 1500 mAh battery in the data logger enables mobile use. To charge the battery, the air quality detector can be connected to a 5 VDC power supply via the micro-USB interface. The air quality detector can continue to be used during the charging process to take measurements. For an optimal and longer-lasting measurement of the air quality detector there is a 1/4 inch connection on the back. With this connection, the air quality detector can be attached to a tripod and aligned.
HIGHLIGHTS
– Measuring range (CO²) 0 … 9999 ppm
– Export of measurement data in CSV format
– Temperature and humidity measurement
– Additionally with carbon monoxide sensor
– Easy to read 2″ LC display
SPECIFICATION
Carbon monoxide (CO) | |
Measuring range* | 0 … 1000 ppm |
Resolution | 1 ppm |
Accuracy | ±5 % of measuring range |
*The CO measurement refers to an ambient condition of 0 … 40 °C / 32 … 104 °F, 15 … 95 % RH, non-condensing |
|
Carbon dioxide (CO²) | |
Measuring range* | 0 … 9999 ppm |
Resolution | 1 ppm |
Accuracy | ±3 % of measured value ± 75 ppm |
*The CO² measurement refers to an ambient condition of 0 … 50 °C / 32 … 122 °F, 0 … 85 % RH, non-condensing |
|
Temperature | |
Measuring range | 0 … 50 °C, 32 … 122 °F |
Resolution | 0.1 °C / °F |
Accuracy | ±2 °C / ±4 °F |
Humidity | |
Measuring range | 0 … 100 % RH |
Resolution | 0.1 % RH |
Accuracy | ±5 % between 0 … 20 % RH |
±3.5 % between 20 … 80 % RH | |
±5 % between 80 … 100 % RH | |
The humidity is based on a wind speed of 1 m/s. The accuracy is maintained after 30 minutes of acclimatization. |
|
Further specifications | |
Display | 2″ LC display |
Measuring rate | 1 Hz |
Memory | for 5000 measuring points |
Storage rate | 1 minute, 15 minutes, 1 hour |
Units | temperature: °C, °F, CO / CO²: ppm |
Alarm when limit values are exceeded | visually and acoustically |
Data export | CSV |
Connection | 1/4“ tripod connection |
Interface | Micro-USB for charging the battery |
and for data transmission | |
Power supply (battery) | 3.7 V, 1500 mAh |
Power supply (power adapter) | primary: 100 … 240 VAC, 50 / 60 Hz, 0.25 A |
secondary: 5 VDC, 1 A | |
Operating conditions | 0 … 45 °C, 32 … 113 °F, <95 % RH, non-condensing |
Storage conditions | -10 … 55 °C, 14 … 131 °F, <95 % RH, non-condensing |
Dimensions | 54 x 215 x 34 mm / 2.1 x 8.4 x 1.3″ |
Weight | 154 g / 5.4 oz |
DELIVERY SCOPE
1 x Micro USB cable
1 x 5V DC power supply
1 x Instruction manual
There are no reviews yet.