Technical Data
Temperature – TC Type K (NiCr-Ni) | |
---|---|
Measuring range | -20 to +500 °C |
Accuracy | ±1 °C (0 to +100 °C) |
Resolution | 0.2 °C |
DC voltage | |
---|---|
Measuring range | 1.0 to 600.0 V |
Resolution | max. 1 mV |
Accuracy | ± (0.8 % of mv + 3 Digit) |
AC voltage | |
---|---|
Measuring range | 1.0 mV to 600.0 V |
Resolution | max. 1 mV |
Accuracy | ± (1 % of mv + 3 Digit) |
DC current | |
---|---|
Measuring range | 0.1 to 600.0 A (clamp)
0.1 to 600.0 μA (measuring cables) |
Resolution | 0.1 (clamp)
0.1 (measuring cables) |
Accuracy | ± (2 % of mv + 5 Digit) (clamp)
± (2 % of mv + 5 Digit) (measuring cables) |
AC current | |
---|---|
Measuring range | 0.1 to 600.0 A (clamp)
0.1 to 600.0 μA (measuring cables) |
Resolution | 0.1 A (clamp)
0.1 μA (measuring cables) |
Accuracy | ± (2 % of mv + 5 Digit) (clamp)
± (1.5 % of mv + 5 Digit) (measuring cables) |
Resistance | |
---|---|
Resolution | max. 0.01 Ohm |
Measuring range | 0.01 to 60.0 MOhm |
Accuracy | ± (1.5 % of mv + 3 Digit) |
Capacitance | |
---|---|
Resolution | max. 0.01 nF |
Measuring range | 2 nF to 60.00 mF |
Accuracy | ± (1.5 % of mv + 5 Digit) |
Frequency | |
---|---|
Resolution | max. 0.1 Hz |
Measuring range | 0.01 Hz to 9999 kHz |
Accuracy | ± (1 % of mv + 1 Digit) |
Active Power | |
---|---|
Measuring range | 0.1 W to 600 kW |
Accuracy | ± (5 % of mv + 5 Digit) |
Resolution | 0.1 W |
Reactive Power | |
---|---|
Measuring range | 0.1 to 600.0 kvar |
Accuracy | ± (10 % of mv + 5 Digit) |
Resolution | 0.1 var |
Apparent Power | |
---|---|
Measuring range | 0.1 VA to 600.0 kVA |
Accuracy | ± 1 Digit |
Resolution | 0.1 VA |
Direct current DC Voltage | |
---|---|
Measuring range | 0.1 W to 600.0 kW |
Accuracy | ± 1 Digit |
Resolution | max. 0.1 W |
Power Factor | |
---|---|
Measuring range | -1.00 to +1.00 |
Accuracy | ± (10 % of mv + 5 Digit) |
Resolution | 0.01 |
General technical data | |
---|---|
Operating humidity | 0 to 80.0 %RH |
Weight | 378 g |
Dimensions | 249 x 96 x 43 mm |
Operating temperature | -10 to +50 °C |
Connectable probes | 1 x temperature probe (adapter required for type K thermocouples) |
System requirements | requires iOS 11.0 or newer; requires Android 6.0 or newer; requires mobile end device with Bluetooth 4.0 |
Product colour | Black |
Standards | EN 61326-1; EN 61010-2-032; EN 61140 |
Battery type | 3 AAA micro batteries |
Display type | LCD (Liquid Crystal Display) |
Display size | 2 lines |
Interface | 2 measuring jacks |
Storage temperature | -15 to +60 °C |
Overvoltage Category | CAT IV 600V; CAT III 1000V |
Authorizations | CSA; CE |
Internal_resistance | 11 MOhm (AC / DC) |
Instrument Measurement Functions | |
---|---|
Diode test | yes |
Continuity testing | yes |
Display ligthing | yes |
Hold | yes |
MinMax | yes |
Power Measurement | yes |
Temperature measurement with adapter | yes |
True RMS | yes |
Inrush current measurement | yes |
Bluetooth | yes |
Display (counts) | 6,000 |
μA current measuring range | yes |
Autom. measurement parameter detection | yes |
There are no reviews yet.