DC Current range |
1000 A, (Max. display 999.9 A) , Basic accuracy: ±1.3% rdg. ±0.3 A (at 30.1 A – 999.9 A)
|
AC Current range |
1000 A (Max. display 999.9 A, 10 Hz to 1 kHz, True RMS), Basic accuracy 45-66 Hz: ±1.8% rdg. ±0.3 A (at 30.1 A – 900.0 A)
|
Crest factor |
1000 A range: 1.5
|
DC+AC Current range |
1000 A (DC, 10 Hz to 1 kHz, True RMS), Basic accuracy DC, 45-66 Hz: ±1.3% rdg. ±1.3 A (at 30.1 A – 900.0 A)
|
DC Power range |
0.000 kVA to 1000 kVA (When using P2000: 0 kVA to 2000 kVA) (Automatically switched based on voltage range), Basic accuracy: ±2.0% rdg. ±20 dgt.
|
DC Voltage range |
600.0 mV to 1000 V (When using P2000: 600.0 V to 2000 V)
|
AC Voltage range |
6.000 V to 1000 V, 4 ranges (15 Hz to 1 kHz, True RMS), Basic accuracy 45 – 66 Hz: ±0.9% rdg. ±0.003 V (at 6 V)
|
DC+AC Voltage range |
6.000 V to 1000 V, 4 ranges, Basic accuracy DC, 45-66 Hz: ±1.0% rdg. ±0.013 V (at 6 V)
|
Resistance range |
600.0 Ω to 6.000 MΩ, 5 ranges, Basic accuracy: ±0.7% rdg. ±0.5 Ω (at 600 Ω)
|
Electrostatic capacity range |
1.000 μF to 1000 μF, 4 ranges, Basic accuracy: ±1.9% rdg. ±0.005 μF (at 1 μF)
|
Frequency range |
9.999 Hz to 999.9 Hz, 3 ranges, Basic accuracy: ±0.1% rdg. ±0.003 Hz (at 9.999 Hz)
|
Temperature (K) |
-40.0°C to 400.0°C, add temperature probe accuracy to basic accuracy of ±0.5% rdg. ±3.0°C
|
Harmonic levels |
[With Z3210 installed] Voltage/Current harmonic levels up to 30th, Content factor, Total harmonic distortion ratio
*Harmonics can be displayed with our free app GENNECT Cross.
|
Other functions |
Continuity check, Diode check, Automatic AC/ DC detection, DC current and DC voltage polarity detection function, MAX/MIN/AVG/ PEAK MAX/PEAK MIN value display, Low-pass filter function, Display value hold, Auto hold, Backlight, Auto power save, Buzzer sound, Zero-adjustment
|
Power supply |
LR03 Alkaline battery ×2
Continuous use: approx. 40 hr (without Z3210 installed), approx. 20 hr. (with Z3210 installed and using wireless communications)
Other conditions: 100 A AC measurement, backlight off, 23°C reference value
|
Core jaw diameter |
φ34 mm (1.34 in)
|
Smallest dimension of jaw cross-section |
9.5 mm (0.37 in) (Range value of 44 mm (1.73 in) from the tip of the jaw)
|
Dimensions and mass |
65 mm (2.56 in) W × 242 mm (9.53 in) H × 35 mm (1.38 in) D mm, 350 g (12.3 oz)
|
Included accessories |
Test Lead L9300, Carrying Case C0203, LR03 Alkaline battery ×2, Instruction Manual ×2, Operating Precautions ×1
|
There are no reviews yet.