- A wireless Fluke Connect®-enabled clamp meter designed specifically for the needs of HVAC technicians
- Offers 200 µA DC current measurements to measure flame rod
- Extends resistance range to measure thermistors up to 60kΩ
The post FLUKE 902 FC TRMS HVAC CLAMP METER 600V appeared first on Adex.
]]>3.0 MIN@180 A
> 1.4 MIN@600 A
Add 2% for CF>400 A
Storage: -40 °C to +60 °C (-40 °F to +140 °F)
Storage: 12,000 m (39,370 ft)
IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V
IEC 61010-2-033: CAT III 1000 V / CAT IV 600 V
The post FLUKE 902 FC TRMS HVAC CLAMP METER 600V appeared first on Adex.
]]>- True RMS AC/DC current measurements
- 34mm diameter jaws
- Measures AC current to 600A or 2500A with optional iFlex probes (sold separately)
The post FLUKE 375FC TRUE RMS AC/DC CLAMP METER 600A(1000V) appeared first on Adex.
]]>The post FLUKE 375FC TRUE RMS AC/DC CLAMP METER 600A(1000V) appeared first on Adex.
]]>- Measure, graph, and record PRTs, thermocouples, and thermistors, supporting a wide range of temperature sensors.
- Accuracy up to ±0.002 °C.
- Quick sample readings in as little as 0.3 seconds.
- 1524 has two channels for simultaneous measurements, doubling productivity.
The post FLUKE 1524 HANDHELD THERMOMETER READOUT appeared first on Adex.
]]>| Specifications | |
| Input channels | 2 |
| Logging | 15,000 time and date stamped; 25 readings with statistics |
| Sample interval (normal) |
1 second |
| Sample interval (fast mode) | 0.3 seconds (see technical manual for details) |
| Sensor types | PRTs, RTDs, thermistors, and thermocouples |
| Thermocouple types | C, E, J, K, L, M, N, T, U, B, R, S |
| Operating temperature | -10°C to 60°C (Best accuracy 13°C to 33°C) |
| Power requirements | 3 AA alkaline batteries |
| Size | 96 x 200 x 47 mm (3.75 x 7.9 x 1.86 in) |
| Weight | 0.65 kg (1.4 lb) |
| Environmental conditions for best accuracy | 13°C to 33°C |
| Millivolt range and accuracy | –10 mV to 75 mV ±(0.005% + 5 μV) |
| Resistance range and accuracy | 0 Ω to 400 Ω ±(0.004% + 0.002 Ω) 200 Ω to 50 kΩ ±(0.01% + 0.5 Ω) 50 kΩ to 500 kΩ ± (0.03%) |
| Temperature coefficient, voltage (–10°C to 13°C, +33°C to 60°C) | ±(0.001%/°C + 1 μV/°C) |
| Temperature coefficient, resistance (–10°C to 13°C, +33°C to 60°C) | 0.0008%/°C + 0.0004 Ω (0 Ω to 400 Ω) 0.002%/°C + 0.1 Ω (0 Ω to 50 kΩ) 0.06%/°C + 0.1 Ω (50 kΩ to 500 kΩ) |
| Excitation current, resistance | 1 mA (0 Ω to 400 Ω) 10 μA (0 Ω to 50 kΩ) 2 µA (50 kΩ to 500 kΩ) |
| Thermocouple Equivalent Temperature Accuracies (Readout Only) | |
| Type B | ±0.85°C from 600°C to 800°C ±0.68°C from 800°C to 1000°C ±0.57°C from 1000°C to 1800°C |
| Type C | ±0.32°C from 100ºC to 550°C ±0.71°C from 550°C to 2300°C |
| Type E | ±0.52°C from -200°C to 0°C ±0.22°C from 0°C to 950°C |
| Type J | ±0.52°C from -200°C to 0°C ±0.23°C from 0°C to 1200°C |
| Type K | ±0.61°C from -200°C to 0°C ±0.24°C from 0°C to 1370°C |
| Type L | ±0.36°C from -200°C to 0°C ±0.23°C from 0°C to 1370°C |
| Type M | ±0.26°C from -20°C to 0°C ±0.25°C from 0°C to 400°C ±0.22°C from 400°C to 1400°C |
| Type N | ±0.72°C from -200°C to 0°C ±0.28°C from 0°C to 1300°C |
| Type R | ±1.09°C from -20°C to 0°C ±0.97°C from 0°C to 500°C ±0.49°C from 500°C to 1750°C |
| Type S | ±1.05°C from -20°C to 0°C ±0.95°C from 0°C to 500°C ±0.56°C from 500°C to 1750°C |
| Type T | ±0.60°C from -200°C to 0°C ±0.25°C from 0°C to 400°C |
| Type U | ±0.54°C from -200°C to 0°C ±0.24°C from 0°C to 400°C |
| Accuracies are based on internal reference junction compensation. Refer to technical manual for equivalent accuracies with an external reference junction. | |
| 1524 Accuracies with Selected Probes (±°C) | |
| -200°C | 5616-12: 0.014 5615-6: 0.025 5627A-12: 0.027 5610-9: n/a |
| 0°C | 5616-12: 0.021 5615-6: 0.021 5627A-12: 0.049 5610-9: 0.009 |
| 100°C | 5616-12: 0.027 5615-6: 0.028 5627A-12: 0.065 5610-9: 0.009 |
| 300°C | 5616-12: 0.040 5615-6: 0.043 5627A-12: 0.103 5610-9: n/a |
| 420°C | 5616-12: 0.050 5615-6: n/a 5627A-12: 0.130 5610-9: n/a |
| Includes readout accuracy, probe calibration, and probe drift | |
| PRT Equivalent Temperature Accuracy (Readout only) | |
| –100°C | ±0.011 |
| 0°C | ±0.015 |
| 100°C | ±0.019 |
| 200°C | ±0.023 |
| 400°C | ±0.031 |
| 600°C | ±0.039 |
| Thermistor Equivalent Temperature Accuracy (Readout Only) | |
| 0°C | ±0.002 |
| 25°C | ±0.003 |
| 50°C | ±0.006 |
| 75°C | ±0.014 |
| 100°C | ±0.030 |
The post FLUKE 1524 HANDHELD THERMOMETER READOUT appeared first on Adex.
]]>- True-rms Electronics Logging Multimeter with TrendCapture quickly documents design performance and graphically displays what happened.
- 50;000 count DMM features a large LCD display; 200 hours of data recording; graphical trend display.
- Dual rated CAT IV 600V; CAT III 1000V
The post FLUKE 287-EUR TRUE RMS ELECTRONICS LOGGING MULTIMETER WITH TRENDCAPTURE appeared first on Adex.
]]>The post FLUKE 287-EUR TRUE RMS ELECTRONICS LOGGING MULTIMETER WITH TRENDCAPTURE appeared first on Adex.
]]>- Measure Volts DC; mA; RTDs; thermocouples; frequency; and ohms.
- Source or simulate Volts DC; mA; RTDs; thermocouples; frequency and ohms.
- Optional pressure modules to source/measure pressure
The post FLUKE 725 MULTIFUNCTION PROCESS CALIBRATOR appeared first on Adex.
]]>The post FLUKE 725 MULTIFUNCTION PROCESS CALIBRATOR appeared first on Adex.
]]>- Overall vibration measurement (10 Hz to 1;000 Hz) for acceleration; velocity and displacement units of measurement for a wide variety of machines
- Memory holds up to 3;500 measurements
- Features Fluke Connect
The post FLUKE 805 FC VIBRATION METER WITH FLUKE CONNECT appeared first on Adex.
]]>High frequency: 80,000 HzReal time clock backupCoin batterySensorSensitivity100 mV g ± 10%Measurement range0.01 g to 50 gLow frequency range (overall measurement)10 Hz to 1,000 HzHigh frequency range4,000 Hz to 20,000 HzResolution0.01 gAccuracyAt 100 Hz ± 5% of measured valueAmplitude UnitsAccelerationg, m/sec²Velocityin/sec, mm/secDisplacementmils, mmInfrared Thermometer (Temperature Measurement)Range-20 °C to 200 °C (-4 °F to 392 °F)Accuracy±2 °C (4 °F)Focal lengthFixed, at ~3.8 cm (1.5″)External SensorNote: Fluke supports but does not provide external sensorsFrequency range10 Hz to 1,000 HzBias voltage (to supply power)20 V dc to 22 V dcBias current (to supply power)Maximum 5 mAFirmwareExternal interfacesUSB 2.0 (full speed) communicationData capacityDatabase on internal flash memoryUpgradeThrough USBMemoryUp to 3,500 measurementsRadiated EmissionElectrostatic discharge: burstStandard EN 61000-4-2Electromagnetic interferenceStandard EN 61000-4-3REStandard CISPR 11, Class AEnvironmentalOperating temperature-20 °C to 50 °C (-4 °F to 122 °F)Storage temperature-30 °C to 80 °C (-22 °F to 176 °F)Operating humidity10% to 95% RH (non-condensing)Operating/storage altitudeSea level to 3,048 meters (10,000 feet)IP ratingIP54Vibration limit500g peakDrop test1 meterGeneral SpecificationsBattery typeAA (2) Lithium Iron DisulfideBattery life250 measurementsSize (L x W x H)24.1 cm x 7.1 cm x 5.8 cm
(9.5 in x 2.8 in x 2.3 in)Weight0.40 kg (0.89 lb)ConnectorsUSB mini-B 7-pin, external sensor jack (SMB connector)
The post FLUKE 805 FC VIBRATION METER WITH FLUKE CONNECT appeared first on Adex.
]]>- Full-featured loop calibrator and 1000V digital multimeter combined into a single handheld unit.
- 20 mA DC current source / loop calibrator / simulator
- Double-sized; dual display
The post FLUKE 789-E PROCESS METER appeared first on Adex.
]]>75% up to 40°C
45% up to 50°C
35% up to 55°C
IEC 1010-1 CAT IV 600 V
1 meter drop test
The post FLUKE 789-E PROCESS METER appeared first on Adex.
]]>- HART Communications capability. Measure: 300V AC/DC; 110mA DC. Source: 15V DC; 22mA DC.
- Measure volts; mA; RTDs; thermocouples; frequency; and ohms to test sensors; transmitters and other instruments
- Bright white dual display. Read both sourced and measured parameters simultaneously.
The post FLUKE 754 HART DOCUMENTING PROCESS CALIBRATOR appeared first on Adex.
]]>100 to 8000.07°C
0.02% + 0.05°C0.14°C
0.04% + 0.10°C200 Ω Pt (385)-200 to 100
100 to 6300.07°C
0.02% + 0.05°C0.14°C
0.04% + 0.10°C500 Ω Pt (385)-200 to 100
100 to 6300.07°C
0.02% + 0.05°C0.14°C
0.04% + 0.10°C1000 Ω Pt (385)-200 to 100
100 to 6300.07°C
0.02% + 0.05°C0.14°C
0.04% + 0.10°C100 Ω Pt (3916)-200 to 100
100 to 6300.07°C
0.02% + 0.05°C0.14°C
0.04% + 0.10°C100 Ω Pt (3926)-200 to 100
100 to 6300.08°C
0.02% + 0.06°C0.16°C
0.04% + 0.12°C10 Ω Cu (427)-100 to 2600.2°C0.4°C120 Ω Ni (672)-80 to 2600.1°C0.2°CSource currentSource °CAllowable current2 1 year2 year 1 mA0.05°C
0.0125% + 0.04°C0.10°C
0.025% + 0.08°C0.1 mA to 10 mA500 μA0.06°C
0.017% + 0.05°C0.12°C
0.034% + 0.10°C0.1 mA to 1 mA250 μA0.06°C
0.017% + 0.05°C0.12°C
0.034% + 0.10°C0.1 mA to 1 mA150 μA0.06 C
0.017% + 0.05°C0.12 C
0.034% + 0.10°C0.1 mA to 1 mA1 mA0.05°C
0.0125% + 0.04°C0.10°C
0.025% + 0.08°C0.1 mA to 10 mA1 mA0.05°C
0.0125% + 0.04°C0.10°C
0.025% + 0.08°C0.1 mA to 10 mA3 mA0.2°C0.4°C0.1 mA to 10 mA1 mA0.04°C0.08°C0.1 mA to 10 mA1. For two and three-wire RTD measurements, add 0.4°C to the specifications.
2. Supports pulsed transmitters and PLCs with pulse times as short as 1 msTemperature, ThermocouplesTypeSource °CMeasure °CSource °C 1 year2 years1 year2 yearsE-250 to -2001.32.00.60.9-200 to -1000.50.80.30.4-100 to 6000.30.40.30.4600 to 10000.40.60.20.3N-200 to -1001.01.50.60.9-100 to 9000.50.80.50.8900 to 13000.60.90.30.4J-210 to -1000.60.90.30.4-100 to 8000.30.40.20.3800 to 12000.50.80.30.3K-200 to -1000.71.00.40.6-100 to 4000.30.40.30.4400 to 12000.50.80.30.41200 to 13720.71.00.30.4T-250 to -2001.72.50.91.4-200 to 00.60.90.40.60 to 4000.30.40.30.4B600 to 8001.32.01.01.5800 to 10001.01.50.81.21000 to 18200.91.30.81.2R-20 to 02.32.81.21.80 to 1001.52.21.11.7100 to 17671.01.50.91.4S-20 to 02.32.81.21.80 to 2001.52.11.11.7200 to 14000.91.40.91.41400 to 17671.11.71.01.5C0 to 8000.60.90.60.9800 to 12000.81.20.71.01200 to 18001.11.60.91.41800 to 23162.03.01.32.0L-200 to -1000.60.90.30.4-100 to 8000.30.40.20.3800 to 9000.50.80.20.3U-200 to 00.60.90.40.60 to 6000.30.40.30.4BP0 to 10001.01.50.40.61000 to 20001.62.40.60.92000 to 25002.03.00.81.2XK-200 to 3000.20.30.20.5300 to 8000.40.60.30.6
The post FLUKE 754 HART DOCUMENTING PROCESS CALIBRATOR appeared first on Adex.
]]>- Loop calibrator that measures 4 to 20 mA signals without breaking the loop
- Features best in class 0.2% accuracy
- Sources 4 to 20 mA signals for testing control system I/O or I/Ps
The post FLUKE 773 ADVANCED MILLIAMP PROCESS CLAMP-METER appeared first on Adex.
]]>(< 18ºC or > 28ºC)
One year for cable and clamp assembly
(measured by clamp)
The post FLUKE 773 ADVANCED MILLIAMP PROCESS CLAMP-METER appeared first on Adex.
]]>- Earth ground ac leakage current measurement
- Heavy-duty clamp jaw stays in alignment and in calibration even in every day, on-the-job industrial environments.
- Identify ac leakage currents without disconnecting the earth ground stake from the grounding system–ideal for system troubleshooting.
The post FLUKE 1630-2 FC EARTH GROUND CLAMP METER 1000V appeared first on Adex.
]]>| Electrical Specifications | ||
| Maximum voltage to earth ground | 1000 V | |
| Battery type | AA alkaline IEC/EN LR6 (x4) | |
| Battery life | More than 15 hours* | |
| * In Ground Resistance measurement mode, with backlight turned off, and RF mode turned off | ||
| Frequency range | 40 Hz to 1 kHz | |
| Ingress protection | IEC/EN 60529: IP30 with jaw closed | |
| LCD | Digital reading | 9999 counts |
| Refresh rate | 4 per second | |
| Operating temperature | -10 °C to + 50 °C | |
| Storage temperature | -20 °C to + 60 °C | |
| Operating humidity | Non condensing (<10 °C) (< 50 °F) | |
| ≤90% RH (at 10 °C to 30 °C [50 °F to 86 °F]) | ||
| ≤75% RH (at 30 °C to 40 °C [86 °F to 104 °F]) | ||
| ≤45% RH (at 40 °C to 50 °C [104 °F to 122 °F]) | ||
| (Non condensing) | ||
| Operating altitude | 2000 m (6561 feet) | |
| Storage altitude | 12 000 m (39,370 feet) | |
| Reference temperature | 23 °C ±5 °C (73 °F ±9 °F) | |
| Temperature coefficient | 0.15% x (specified accuracy)/ °C (<18 °C or >28 °C [<64.4 °F or >82.4 °F]) | |
| Overload indication | OL | |
| Data logging capacity | Minimum of 32,760 measurements | |
| Data logging interval | 1 second to 59 minutes and 59 seconds | |
| Display reading specification with standard loop resistance | ||
| Input (Ω) | Minimum | Maximum |
| 0.474 | 0.417 | 0.531 |
| 0.5 | 0.443 | 0.558 |
| 10 | 9.55 | 10.45 |
| 100 | 96 | 104 |
| Safety | ||
| General | IEC/EN 61010-1: Pollution Degree 2 IEC/EN 61557-1 | |
| Measurement | IEC/EN 61010-2-032: CAT IV 600 V / CAT III 1000 V | |
| Current clamp for leakage current measurements | IEC/EN 61557-13: Class 2, ≤30 A/m | |
| Resistance to earth | IEC/EN 61557-5 | |
| Effectiveness of thepProtective measures | IEC/EN 61557-16 | |
| Electromagnetic compatibility (EMC) | International | IEC/EN 61326-1: Portable Electromagnetic Environment |
| CISPR 11: Group 1, Class B, IEC/EN 61326-2-2 | ||
| Korea (KCC) | Class A equipment (Industrial Broadcast & Communications Equipment) | |
| USA (FCC) | 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103 | |
| Wireless Radio | ||
| Frequency range | 2412 MHz to 2462 MHz | |
| Output power | <10 mW | |
| Radio frequency certification | FCC ID:T68-FBLE IC:6627A-FBLE | |
| General Specifications | ||
| Conductor size | 40 mm (1.57 in) approximately | |
| Dimensions (L x W x H) | 283 x 105 x 48 mm (11.1 x 4.1 x 1.9 in) | |
| Weight | 880g (31 oz) | |
| Warranty | One year | |
| Earth Ground Loop Resistance | ||
| Range | Accuracy1 ± (% of reading + Ω) | |
| 0.025 Ω to 0.249 Ω | 1.5% + 0.02 Ω | |
| 0.250 Ω to 0.999 Ω | 1.5% + 0.05 Ω | |
| 1.000 Ω to 9.999 Ω | 1.5% + 0.10 Ω | |
| 10.00 Ω to 49.99 Ω | 1.5% + 0.30 Ω | |
| 50.00 Ω to 99.99 Ω | 1.5% + 0.50 Ω | |
| 100.0 Ω to 199.9 Ω | 3.0% + 1.0 Ω | |
| 200.0 Ω to 399.9 Ω | 5.0% + 5.0 Ω | |
| 400 Ω to 599 Ω | 10.0% + 10 Ω | |
| 600 Ω to 1500 Ω | 20.00% | |
| 1 Loop resistance with no inductance, conductor centered and perpendicular to jaw | ||
| Earth ground leakage current mA | ||
| Autorange 50/60 Hz, True rms, crest factor CF ≤3 | ||
| Range | Resolution | Accuracy1 ± (% of reading + mA) |
| 0.200 mA to 3.999 mA | 1 μA | 2.0% + 0.05 mA |
| 4.00 mA to 39.99 mA | 10 μA | 2.0% + 0.03 mA |
| 40.0 mA to 399.9 mA | 100 μA | 2.0% + 0.3 mA |
| 0.400 A to 3.999 A | 1 mA | 2.0% + 3 mA |
| 4.00 A to 39.99 A | 10 mA | 2.0% + 30 mA |