Hioki Digital Multimeter DT4253

Availability : in stock
Share:

Hioki DT4253 digital multimeter is used for testing of Heating, Ventilation and Air Conditioning (HVAC) devices.

The Hioki DT4200 Digital Multimeter Series consist of a complete lineup of 9 models ranging from professional to industrial to pocket meters, delivering a super fast response rate and safety features that take electrical testing to a higher level.

  • DT4253 Multimeter is designed specifically for HVAC Testing.
  • Used to measure DC current ranging 60μA to 60mA .
  • measurement data can be downloaded and viewed on a computer.
  • Multiple measurement functions such as Temperature, Capacitance and Frequency.

 

 

DC Voltage range

600.0 mV to 1000 V
5 ranges, Basic accuracy: ±0.3 % rdg. ±5 dgt.

AC Voltage range

6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz to 1 kHz
Basic accuracy 40 – 500 Hz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3)

AUTO AC/DCV

Yes

Resistance range

600.0 Ω to 60.00 MΩ, 6 ranges, Basic accuracy: ±0.7 % rdg. ±5 dgt.

DC Current range

60.00 μA to 60.00 mA, 4 ranges,
Basic accuracy: ±0.8 % rdg. ±5 dgt.

From 4 to 20mA Percentage conversion display

Yes

AC Current range (use with Clamp on probes)

10.00 A to 1000 A, 7 ranges, Add the Clamp on probe accuracy to basic accuracy 40 – 1 kHz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3)

Temperature (thermocouples)

K: -40.0 to 400.0 °C , Add the Temperature probe accuracy to basic accuracy: ±0.5 % rdg. ±2 °C

Voltage detection

N/A

Capacitance range

1.000 μF to 10.00 mF, 5 ranges, Basic accuracy: ±1.9 % rdg. ±5 dgt.

Frequency range

99.99 Hz to 99.99 kHz, 4 ranges (limited by the minimum detectable voltage),
Basic accuracy: ±0.1 % rdg. ±1 dgt.

Continuity check

Continuity threshold [ON]: 25 Ω or less ,
[OFF]: 245 Ω or more,
Response time: 0.5 ms or more

Diode test

Open terminal voltage: 5.0 V or less, Testing current 0.5 mA or less,
Threshold of forward voltage: 0.15 V to 1.5 V

Other functions

Filter function, display value hold, auto hold, MAX/MIN/Average value display, relative value display, auto-power save, USB communication (option), 4-20 mA percentage conversion

Display

Main and Sub displays: 4-digits LCD, max. 6000 digits, bar graph

Display refresh rates

5 times/s (Capacitance measurement: 0.05 to 5 times/s, depending on measured value, Frequency: 1 to 2 time/s)

Power supply

LR03 alkaline batteries ×4, Continuous use: 130 hours (backlight OFF)

Dimensions and mass

84 mm (3.31 in)W × 174 mm (6.85 in)H× 52 mm (2.05 in)D,
390 g (13.8 oz) (including batteries and holster)

Included accessories

Test lead L9207-10 ×1, Holster ×1, Instruction manual ×1, LR03 alkaline battery ×4

There are no reviews yet.