Specifications of UT513B/UT513C 5kV Insulation Resistance Testers
Rated voltage | UT513B | UT513C |
250V | <0.25MΩ: reference only | <0.25MΩ: reference only |
0.25MΩ~2.49GΩ: ±5%+5) | 0.25MΩ~4.99GΩ: ±(5%+5) | |
2.50GΩ~24.9GΩ: ±(10%+10) | 5.00GΩ~49.9GΩ: ±(10%+10) | |
25.0GΩ~100GΩ: reference only | 50.0GΩ~250GΩ: reference only | |
500V | <0.50MΩ: reference only | <0.50MΩ: reference only |
0.50MΩ~4.99GΩ: ±(5%+5) | 0.50MΩ~4.99GΩ: ±(5%+5) | |
5.00GΩ~49.9GΩ: ±(10%+10) | 5.00GΩ~99.9GΩ: ±(10%+10) | |
50.0GΩ~200GΩ: reference only | 100GΩ~500GΩ: reference only | |
1000V | <1.00MΩ: reference only | <1.00MΩ: reference only |
1.00MΩ~9.99GΩ: ±(5%+5) | 1.00MΩ~9.99GΩ: ±(5%+5) | |
10.0GΩ~99.9GΩ: ±(10%+10) | 10.0GΩ~199GΩ: ±(10%+10) | |
100GΩ~400GΩ: reference only | 200GΩ~1.00TΩ: reference only | |
2500V | <2.50MΩ: reference only | <2.50MΩ: reference only |
2.50MΩ~24.9GΩ: ±(5%+5) | 2.50MΩ~24.9GΩ: ±(5%+5) | |
25.0GΩ~249GΩ: ±(15%+10) | 25.0GΩ~499GΩ: ±(15%+10) | |
250GΩ~1.00TΩ: reference only | 500GΩ~2.50TΩ: reference only | |
5000V | <5.00MΩ: reference only | <5.00MΩ: reference only |
5.00MΩ~49.9GΩ: ±(5%+5) | 5.00MΩ~49.9GΩ: ±(5%+5) | |
50.0GΩ~499GΩ: ±(15%+20) | 50.0GΩ~999GΩ: ±(15%+20) | |
500GΩ~2.00TΩ: reference only | 1.00TΩ~5.00TΩ: reference only | |
Capacitance test | NA | 0.01uF~15.0uF |
Output voltage | stepping voltage range | Step by 10% of each range each time, and adjust the voltage range to 50%~120% of each range UT513B + UT513C: Display accuracy:±(10% read+10V) Output accuracy:+(0%~20%) |
250V | 250V, 275V, 300V | |
500V | 250V, 300V, 350V, 400V, 450V, 500V, 550V, 600V | |
1000V | 500V, 600V, 700V, 800V, 900V, 1000V, 1100V, 1200V | |
2500V | 1250V, 1500V, 1750V, 2000V, 2250V, 2500V, 2750V, 3000V | |
5000V | 2500V, 3000V, 3500V, 4000V, 4500V, 5000V | |
DC voltage | 30~1000VDC: ±(3%+5) | |
AC voltage | 30~750VAC(50Hz/60Hz): ±(3%+5) | |
Current | 0.01nA~3.5mA | 0.01nA~5.0mA |
Short-circuit current | about 3.5mA | about 5.0mA |
Main features | ||
PI test | √ | √ |
DAR test | √ | √ |
Timing measurement | √ | √ |
Resistance Comparison | √ | √ |
Voltage step | √ | √ |
Voltage monitoring (of external object) | Monitor the voltage of measured object and the discharge state after testing. If voltage is higher than 36V, it is forbidden to test for protecting the tester and the operator | |
Timer testing | Record testing time automatically. Timing range: 0s~99m and 59s | |
Data storage | 999 set | 999 set |
USB interface (data transmission) | √ | √ |
Bluetooth APP | N/A | √ |
Low Battery indication | √ | √ |
Auto power off | Around 15 minutes | Around 15 minutes |
Overvoltage category | CAT Ⅳ 600V | CAT Ⅳ 600V |
Certificates | CE & UKCA | CE & UKCA |
General Characteristics | ||
Power supply | 14.8V,5200mAh lithium battery | |
Product Color | Black+Red | |
Product Weight | About 1800g (including battery) | |
Product Dimension | 238 x 166 x 90.5mm(L*W*D) | |
Package quantity | 1pcs | |
Package Size | 415×155×370mm(L*W*D) | |
Accessories | User manual 1pcs; Test lead(red, black, green, 1 for each) 3pcs; USB cable 1pcs; Lithium battery charger 1pcs; Lithium battery pack 1pcs; Adapting charging stand(optional); Carrying strap 1pcs; |