Coating Thickness Gauge PCE-CT 80-F5N3
DESCRIPTION
Integrated data storage
The coating thickness gauge is also ideal for immediately determining and assessing accident damage to vehicles, for example, but the coating thickness gauge can also be used optimally in the industrial sector for incoming and outgoing inspection and material testing in production.
The ergonomically designed coating thickness gauge with external sensor allows you to rapidly determine measurement results with high accuracy. The coating thickness gauge measures non-magnetic layers such as paint, plastic, chrome, copper, zinc, enamel, etc. on steel/iron, as well as non-conductive layers such as paint, plastic, enamel, paper, glass, rubber, etc. on copper, aluminum , brass and stainless steel, as well as anodized aluminum.
HIGHLIGHTS
– Measurements cannot be influenced by vibrations
– Practical V-groove on the measuring heads
– Ergonomic design
– Warning message for measurements outside the maximum measuring range
– Wear-resistant, spring-mounted measuring head for precise measuring results
SPECIFICATION
Measuring range | Fe: 0 … 5000 µm |
NFe: 0 … 3000 µm | |
Accuracy | ±(2 % of reading + 1 µm) |
Resolution | 0.1 µm (<100 µm) |
1 µm (>100 µm) | |
Measurable materials | For measurements on iron/steel and non-ferrous metals |
Min. radius of curvature convex | 5 mm / 0.19″ |
Min. radius of curvature concave | 25 mm / 0.98″ |
Min. measuring surface | Ø17 mm / 0.67″ |
Min. substrate thickness | 0.2 mm / 0.008″ (on magnetic materials) |
0.05 mm / 0.002″ (on non-magnetic materials) | |
Probe mode | Autom. mode with material detection (Fe + NFe) |
Magnetic mode (Fe) | |
Eddy current mode (NFe) | |
Calibration | Multipoint calibration (1 … 4 points for each group) |
Zero-point calibration | |
Units | µm, mm, mils |
Data transfer | USB 2.0 |
Memory | A volatile measuring group (DIR mode) |
Four measuring groups with autom. storage and max. 2000 readings (GEN mode) | |
Statistical functions | Number of measured values, mean, minimum, maximum, standard deviation |
Alarm | Display when the adjustable upper and lower alarm limits are exceeded |
Operating time | Autom. shutdown mode (3 min.) |
Power supply | 3 x 1.5 V AAA batteries |
Display | 128 x 128 px LCD display |
Indicators | Battery status |
Fault detection | |
Operating conditions | 0 … +50 °C / 32 … 122 °F |
20 … 90 % RH non-condensing | |
Storage conditions | -10 … +60 °C / 14 … 140 °F |
20 … 90 % RH non-condensing | |
Dimensions | 143 x 71 x 37 mm / 5.6 x 2.8 x 1.5″ (L x W x H) |
Weight | With sensor and batteries: ca. 271 g / 9.5 oz |
DELIVERY SCOPE
3 x AAA batteries
1 x Instruction manual
1 x Carrying case
1 x Set of standard foils
1 x Calibration plates (Fe and NFe)
Reviews
There are no reviews yet