FLUKE 87-V-E2K-EUR INDUSTRIAL ELECTRICIANS COMBO KIT
# 87-V-E2K-EUR
- True RMS;
- Analog Bargraph
- Digital Display; Backlight; 1000V AC/DC
- Measure up to 10A; 20A for up to 30 seconds.
Description
Reviews (0)
| Specifications | ||
| Voltage DC | Maximum Voltage | 1000 V |
| Accuracy | ±(0.05% + 1) | |
| Maximum Resolution | 10 µV | |
| Voltage AC | Maximum Voltage | 1000 V |
| Accuracy | ±(0.7% + 2) True RMS | |
| AC Bandwidth | 20 kHz with low pass filter; 3 db @ 1 kHz | |
| Maximum Resolution | 0.1 mV | |
| Current DC | Maximum Amps | 10 A (20 A for 30 seconds maximum) |
| Amps Accuracy | ±(0.2% + 2) | |
| Maximum Resolution | 0.01 µA | |
| Current AC | Maximum Amps | 10 A (20 A for 30 seconds maximum) |
| Amps Accuracy | ±(1.0% + 2) True RMS | |
| Maximum Resolution | 0.1 µA | |
| Resistance | Maximum Resistance | 50 MΩ |
| Accuracy | ±(0.2% + 1) | |
| Maximum Resolution | 0.1Ω | |
| Capacitance | Maximum Capacitance | 9,999 µF |
| Accuracy | ±(1% + 2) | |
| Maximum Resolution | 0.01 nF | |
| Frequency | Maximum Frequency | 200 kHz |
| Accuracy | ±(0.005% + 1) | |
| Maximum Resolution | 0.01 Hz | |
| Duty Cycle | Maximum Duty Cycle | 99.9% |
| Accuracy | ±(0.2% per khz +0.1%) | |
| Maximum Resolution | 0.1% | |
| Temperature Measurement | -200.0°C – 1090°C -328.0°F – 1994.0°F excluding probe |
|
| 80 BK Temperature Probe | -40.0°C – 260°C -40.0°F – 500°F, 2.2°C or 2% whichever is greater |
|
| Conductance | Maximum Conductance | 60.00 nS |
| Accuracy | ±(1.0% + 10) | |
| Maximum Resolution | 0.01 nS | |
| Diode | Range | 3 V |
| Resolution | 1 mV | |
| Accuracy | ±(2% + 1) | |
| Duty Cycle Range | Accuracy | Within ±(02% per kHz +0.1%) |
| Environmental Specifications | ||
| Operating Temperature | -20°C to +55°C | |
| Storage Temperature | -40°C to +60°C | |
| Humidity (Without Condensation) | 0% – 90% (0°C – 35°C) 0% – 70% (35°C – 55°C) |
|
| Operating Altitude | 2000 m | |
| Safety Specifications | ||
| Overvoltage category | EN 61010-1 to 1000 V CAT III, 600V CAT IV | |
| Agency Approvals | UL, CSA, TÜV, VDE listed | |
| Mechanical and General Specifications | ||
| Size | 201 x 98 x 52 mm (with holster) | |
| Weight | 355 g 624 g – with holster |
|
| Display | Digital | 6000 counts updates 4/sec. 19,999 counts in high-resolution mode |
| Analog | 32 segments, updates 40/sec. | |
| Frequency | 19,999 counts, updates 3/sec at > 10 Hz | |
| Battery Life | Alkaline | ~400 hours typical, without backlight |
| Shock | 1 Meter drop per IEC 61010-1:2001 | |
| Vibration | Per MIL-PRF-28800 for a Class 2 instrument | |



Reviews