Hioki DT4222 Digital Multimeter TRMS 600V
The Hioki DT4200 Digital Multimeter Series consist of a complete lineup of 9 models ranging from professional to industrial to pocket meters, delivering a super fast response rate and safety features that take electrical testing to a higher level. The DT4222 is a pocket-sized digital multimeter designed specifically for general purpose testing, with ±0.5% DC V accuracy and wide 40 Hz to 1 kHz AC V bandwidth.
CAT IV 300 V, CAT III 600 V
Key Features
• Achieving a high level of safety in a compact body and lightweight design
• Resistance, Capacitance measurement and diode testing (DT4222)
• Robust design capable of withstanding a drop from a height of 1 m
• Test leads conveniently wrap around the back
• ±0.5% DC V basic accuracy, wide 40 Hz to 1 kHz AC V frequency characteristics
• Low-pass filter cuts high harmonics (when measuring inverter fundamental waveforms)
• Broad -10 to 50°C (14°F to 122°F) operating temperature range
DC Voltage range | 600.0 mV to 600.0 V, 4 ranges, Basic accuracy: ±0.5 % rdg. ±5 dgt. |
---|---|
AC Voltage range | 6.000 V to 600.0 V, 3 ranges, Frequency characteristics: 40 Hz – 1 kHz Basic accuracy 40 – 500 Hz : ±1.0 % rdg. ±3 dgt. (True RMS, crest factor 3) |
Resistance range | 600.0 Ω to 60.00 MΩ, 6 ranges, Basic accuracy: ±0.9 % rdg. ±5 dgt. |
Capacitance range | 1.000 μF to 10.00 mF, 5 ranges, Basic accuracy: ±1.9 % rdg. ±5 dgt. |
Frequency range | AC V measurement: 99.99 Hz (5 Hz or more) to 9.999 kHz, 3 ranges Basic accuracy: ±0.1 % rdg. ±2 dgt. |
Continuity Check | Continuity threshold [ON]: 25 Ω or less (buzzer sound), [OFF]: 245 Ω or more Response time: 0.5 ms or more |
Diode test | Open terminal voltage: 2.5 V or less, Testing current 0.5 mA or less, Threshold of forward voltage: 0.15 V to 1.5 V |
Voltage Detection | N/A |
Other functions | Filter function, display value hold, relative value display, auto-power save |
Display | Main and Sub displays: 4-digits LCD, max. 6000 digits, bar graph |
Display refresh rates | 5 times/s (Capacitance measurement: 0.05 to 5 times/s, depending on measured value, Frequency: 1 to 2 time/s ) |
Power supply | LR03 alkaline batteries ×1, Continuous use: 40 hours (back light OFF) |
Dimensions and mass | 72 mm (2.83 in) W × 149 mm (5.87 in) H× 38 mm (1.50 in) D,190 g (6.7 oz) (with batteries and holster) |
Included accessories | Test Lead DT4911 ×1, Holster ×1, Instruction manual ×1, LR03 alkaline battery ×1 |
Reviews