Installationstester PCE-ITE 55A
CHARACTERISTICS
DESCRIPTION
The installation tester allows the loop resistance to be measured quickly and accurately to ensure that in the event of a fault current there is sufficient resistance to ensure a safe shutdown. In addition, measuring the protective conductor resistance enables the continuity of conductors and connections to be checked. A graphical representation of the wiring helps the operator make measurements correctly.
The installation tester offers a user-friendly interface, clear display elements and a robust construction to meet the needs of various environments. By adhering to international standards, it ensures safe and reliable assessment of electrical installations according to the highest industry standards.
SPECIFICATION
| Alternating voltage AC | |
| Measuring range | 0V…+550V | 
| resolution | 1V | 
| accuracy | ±(2% of mv. + 2 digits) | 
| Insulation resistance | |
| Test voltage DC | 50V | 
| Measuring range | 0.1MΩ…+80MΩ | 
| resolution | 0.001 MΩ (0.100 … 1.999) 0.01 MΩ (2.00 … 80.00) | 
| accuracy | ±(5% of mv. + 3 digits) | 
| Insulation resistance | |
| Test voltage DC | 100V, 250V | 
| Measuring range | 0.1MΩ…+199.9MΩ | 
| resolution | 0.001 MΩ (0.100 … 1.999) 0.01 MΩ (2.00 … 99.99) 0.1 MΩ (100.0 … 199.9) | 
| accuracy | ±(5% of mv. + 3 digits) | 
| Insulation resistance | |
| Test voltage DC | 500V, 1000V | 
| Measuring range | 0.1MΩ…+199.9MΩ | 
| resolution | 0.001 MΩ (0.100 … 1.999) 0.01 MΩ (2.00 … 99.99) 0.1 MΩ (100.0 … 199.9) | 
| accuracy | ±(2% of mv. + 3 digits) | 
| Insulation resistance | |
| Test voltage DC | 500V, 1000V | 
| Measuring range | +200MΩ … +999MΩ | 
| resolution | 1MΩ | 
| accuracy | ±(10% of mv.) | 
| Continuity test | |
| Measuring range | 0.1Ω … +20Ω | 
| resolution | 0.01Ω | 
| accuracy | ±(3% of mv. + 3 digits) | 
| Continuity test | |
| Measuring range | +20Ω … +1999Ω | 
| resolution | 0.1 Ω (20.0 Ω … 99.9 Ω) 1 Ω (100 Ω … 1999 Ω) | 
| accuracy | ±(5% of mv.) | 
| impedance | |
| Measuring range | 0.25Ω…+9999Ω | 
| resolution | 0.01 Ω (0.20 … 19.99) 0.1 Ω (20.0 … 99.9) 1 Ω (100 … 9999) | 
| accuracy | ±(5% of mv. + 5 digits) | 
| frequency | |
| Measuring range | +10 Hz … +499.9 Hz | 
| resolution | 0.1Hz | 
| accuracy | 0.2% + 1 digit | 
| General technical data | |
| Display type | TFT color display | 
| Display size | 3.3 inches | 
| Norm(s) | EN61557, DIN VDE 0100 | 
| Operating time | 3 p.m | 
| Automatic switch-off adjustable | 0.5 … 60 min. | 
| Automatic switch-off can be deactivated | Yes | 
| RCD test current characteristic | A, AC | 
| RCD tripping current | 650mA, 500mA, 30mA, 6mA, 300mA, 10mA, 1000mA, 100mA | 
| RCD trip time | 0…500 ms | 
| Touch voltage | 0…99.9V | 
| Menu language | German English | 
| Protection class (device) | IP42 | 
| Power supply | Battery, power supply | 
| Weight | 1300g | 
| Device weight with scope of delivery | 1750g | 
| Device weight including scope of delivery and outer packaging | 1930 g | 
| Dimensions (L x W x H) | 250x135x107mm | 
| Operating conditions | 0 … 40 °C, 95% RH | 
| Storage conditions | -10 … 70 °C, 90% RH | 
 
        


 
															 
                
Reviews