Lutron 9904 SD Indoor Air Quality Monitor

Lutron 9904 SD Indoor Air Quality Monitor is an ongoing recorder in which the SD Card can record three sorts of information CO2/Humidity/Temp, alongside the time data into one Excel document in the meantime. A manual datalogger is accessible which it can set the distinctive area no. ( position 1 to position 99 )

Applications: Pharmaceutical laboratories, Food Laboratories, Universities, and for Research applications, HVAC, Agriculture, Commercial Buildings.

Description
Reviews (0)

Discription

Lutron 9904 SD Indoor Air Quality Monitor is a Multifunctional Meter that can download 3 different data from the same SD card along with the time information in one excel. This indoor air quality monitor Real-time recorder with an Alarm setting with a beep sound output.

Electrical Specifications:

CO2 ( Carbon dioxide )

23 ± 5 Deg C

Range0 to 6,000 ppm
Resolution1 ppm
Accuracy± 40 ppm, < 1,000 ppm.
± 5% of reading

> 1,000 ppm 3,000 ppm.

± 250 ppm typically

> 3,000 ppm, reference only

Repeatability± 20 ppm < 3,000 ppm.
Humidity/Range5 % to 95 % R.H
Resolution0.1 % R.H
Accuracy70% RH : ± (3% reading + 1% RH), < 70% RH : ± 3% RH
TemperatureRange0 to 50 Deg C ,32 to 122 Deg F
Resolution0.1 degree
Accuracy± 0.8  Deg C, ± 1.5 Deg F
Dew Point Temp. ( Humidity )Range-25.3 to 48.9 Deg C
Resolution0.1 Deg C
Wet bulb Temp. ( Humidity )Range-21.6 to 50.0 Deg C
Resolution0.1 Deg C

Specification

ManufacturerLutron
Model No9904 SD
Measuring ParametersCarbon Dioxide, Dew Point Temperature, Temperature, Relative Humidity, Wet Bulb Temperature
Carbon Dioxide0 to 6000 ppm
Accuracy+/-5% of Reading
Resolution1 PPM
Temperature0 to +50°C
Accuracy+/-0.8 Deg.C
Resolution0.1 °C
Relative Humidity5 to 95% RH
Accuracy+/-3% RH
Resolution0.1 % R.H.
Wet Bulb Temperature-21.6 to 50.0 Deg.C
AccuracySum accuracy value of Humidity and Temperature Measurement
Resolution0.1 Deg.C
Dew Point Temperature-25.3 to 48.9 Deg.C
AccuracySum accuracy value of Humidity and Temperature Measurement
Resolution0.1 Deg.C
DisplayLCD with green backlight
Sampling TimeApprox. 1 second
Operating Temperature0 to 50 Deg C( 32 to 122 ) Deg F
Operating HumidityLess than 80% R.H.
Data HoldFreeze the display reading.
Memory RecallMaximum & Minimum value.
Data OutputRS 232/USB PC computer interface,
SensorsCO2:NDIR * Nondispersive infrared sensor,Humidity: Precision capacitance sensor , Temp: Precision thermistor
CircuitCustom one-chip of microprocessor LSI circuit.
Power SupplyAAlkaline or heavy duty DC 1.5 V battery ( UM3, AA ) x 6 PCs, or equivalent
AccessoriesIncluded: Instructional Manual,Carring case, CO2 & Humidity Probe
Optional AccessoriesRS232 cable, UPCB-02, USB cable, USB-01, Data Acquisition software, SW-U801-WIN
Memory CardSD memory card. 1 GB to 16 GB.
Dimensions177 x 68 x 45 mm
Weight350 Grams