Uni-T Digital Clamp Meter AC/DC 600A

Availability : in stock
Share:

UT200+ series digital clamp meters are designed according to EN61010-2010 CAT II 600V/CAT III 300V, featuring overload protection, high reliability, high safety and high accuracy. These meters can be used to measure high-voltage frequency, temperature, AC/DC current, etc.

Models in UT200+ Series: UT201+, UT202+, UT202A+, UT203+, UT204+

Specifications of UT200+ Series 400A/600A Digital Clamp Meters

Specifications Range UT201+ UT202+ UT202A+ UT203+ UT204+
AC current (A) 400A ±(2%+10) ±(2%+10) ±(2.5%+5)
600A ±(2%+10) ±(2.5%+5)
AC current frequency (Hz) 50Hz~100Hz ±(1%+5) ±(1%+5) ±(1%+5)
DC current (A) 400A ±(2.5%+5)
600A ±(2.5%+5)
AC voltage (V) 600V ±(0.8%+5) ±(0.8%+5) ±(0.8%+5) ±(0.8%+5) ±(0.8%+5)
AC voltage frequency(Hz) 10Hz~10kHz ±(1%+5) ±(1%+5) ±(1%+5)
10Hz~60kHz ±(0.5%+2) ±(0.5%+2)
DC voltage (A) 600V ±(0.5%+2) ±(0.5%+2) ±(0.5%+2) ±(0.5%+2) ±(0.5%+2)
Resistance (Ω) 40MΩ ±(0.8%+2) ±(0.8%+2) ±(0.8%+2)
60MΩ ±(0.8%+2) ±(0.8%+2)
Capacitance (F) 4mF ±(4%+5)
40mF ±(4%+5)
60mF ±(4%+5) ±(4%+5)
Temperature (℃) -40℃~1000℃ ±(1.5%+5) ±(1.5%+5)
Frequency (Hz) 10Hz~10MHz ±(0.1%+4) ±(0.1%+4) ±(0.1%+4)
Features
Display count 4000 4000 6000 4000 6000
Auto range
Jaw opening 28mm 28mm 28mm 28mm 28mm
True RMS
NCV
Live wire test
Continuity test
Diode
MAX/MIN
Relative mode
Zero mode
Data hold
Low battery indication
Auto power off
General Characteristics
Power 1.5V battery (R03) x 2
Display 37mm x 25mm
Product color Red and grey
Product net weight UT201+/UT202+/UT202A+:248g; UT203+/UT204+:235g
Product size 215mm x 63mm x 36mm
Standard accessories Batteries, test leads, Themocouple (UT202+/UT204+)
Standard individual packing Gift box, Carring bag, English manual
Standard quantity per carton 40pcs
Standard carton measurement 485mm x 295mm x 385mm
Standard carton gross weight UT202A+: 17.8kg; UT203+: 16.8kg; UT201+/202+/204+: 17.3kg