Lutron AQ-9901SD Air Quality Monitor

Lutron AQ-9901SD Air Quality Monitor offers exact and effective chronicle. In this air quality sensor data gets saved into the SD memory card and can be downloaded to Excel. With its exceptional level development, this air quality meter is certain to provide durability.

Applications: Greenhouses, Residential, Warehouse, Garages, Offices, Industries.

Description
Reviews (0)

Discription

Lutron AQ-9901SD Air Quality Monitor is a Real-time recorder that saves the information into the SD memory card and can be downloaded to Excel. At a similar time, the SD memory card can record 4 test information (%RH/CO2/O2/Temp. or  %RH/CO2/CO/Temp. ) including the time data into one Excel record.

Features of Air Quality Monitor:

  • This Air Quality Monitor Alarm setting with beeper sound.
  • The sampling time for the information recorder is 2 seconds to 8 hours.
  • Complete set with 4 tests: CO2/Temp. test, O2/Temp. test, CO/Temp. probe, Humidity/Temp, test, fundamental meter, and the hard conveying case.
  • This Lutron Air Quality Monitor has a Separate test and is simple for remote estimation.
  • Meter can participate with a 2 GB to 16 GB SD card, SD card is discretionary.

Specification

ManufacturerLutron
Model NoAQ-9901SD
Measuring ParametersCarbon Dioxide, Carbon Monoxide, Dew Point Temperature, Dew Point/ Wet Bulb, Oxygen (In Air), Relative Humidity, Temperature
Carbon Dioxide0 to 4,000 ppm
Resolution_11 ppm
Accuracy± 40 ppm
Carbon Monoxide0 to 1,000 ppm
Resolution_21 ppm
Accuracy± ( 5% + 2 ppm )
Dew Point Temperature-25.3℃ to 48.9℃
Resolution_40.1°C
Wet Bulb Temperature-21.6℃ to 50.0℃
Resolution0.1℃
Oxygen0 to 30% O2
Accuracy± ( 1 % reading + 0.2 % O2 ).
Resolution_30.1% O2
Humidity5 to 95% R.H
Accuracy70% RH : ≧ ± (3% reading + 1% RH)
Resolution_50.1% R.H
Temperature0℃ to 50℃
Accuracy± 0.8℃
Resolution_60.1°C
Operating Temperature0℃ to 50℃
Operating HumidityLess than 80% R.H.
Sampling TimeApprox. 1 second
SensorsCO2 : NDIR * Nondispersive infrared sensor, Humidity : Precision capacitance sensor, O2: Galvanic cell type, CO : Galvanic cell type, Temp. Precision thermistor
Data HoldFreeze the display reading.
CircuitCustom one-chip of microprocessor LSI circuit.
MemorySD memory card. 1 GB to 16 GB.
Memory RecallMaximum & Minimum value.
Data OutputRS 232/USB PC computer interface,
Power SupplyDC 1.5 V battery ( UM3, AA ) x 6 pcs, or equivalent.
AccessoriesInstruction manual, Hard carrying case, CA-08, CO2 probe, Humidity probe, O2 probe, CO probe
Dimension177 X 68 X 45 mm, CO Probe: 150 x 38 x 38 mm, CO2 Probe: 190 x 38 x 28 mm, Humidity Probe: 197 mm in length, O2 Probe: 150 x 38 x 38 mm
Weight350 g/0.77 LB