Lutron TU2016 Turbidity Meter

Lutron TU-2016 Turbidity Meter measures the free and total chlorine. This Turbidity meter has an advanced optical system that allows the most accurate and repeatable reading. This unit is splash and waterproof on the front panel. This Digital Turbidity Monitor has a jumbo LCD screen that provides easy readout. The NTU Meter microprocessor circuit assures great accuracy.
Application: Test municipal water, Drinking water, Swimming water, Wastewater treatment, Industrial processes, Environmental Monitoring, Research on aquatic ecosystems, Food purposes, Beverage Industries etc

Description
Reviews (0)

Discription

Lutron TU-2016 Turbidity Meter is used to measure the free and total chlorine. This Lutron Turbidity meter has an advanced optical system that allows the most accurate and repeatable reading. This Digital nephelometric has a jumbo LCD screen that provides easy readout. The microprocessor circuit assures great accuracy. This is a Portable NTU device that provides accurate information to the user. The turbidity meter for water and solutions for food purposes is suitable for evaluating the degree of cloudiness of drinks.

Features Of Lutron TU2016 Turbidity Meter:

  • The unique optics structure enables the instrument to read the low value of turbidity to the high level of up to 1,000 NTU.
  • This Portable nephelometer has Four operation buttons and two calibration points, easy to operate, and guarantees the spec. accuracy.
  • This Portable Turbidity Meter has a Jumbo LCD and an easy readout.
  • The microprocessor circuit assures maximum possible accuracy and provides special functions and features.
  • Battery operating system for field and on-site testing convenience.
  • Data hold function for freezing the desired value on the display.

Specification

ManufacturerLutron
Model NoTU 2016
Measuring ParametersTurbidity
Range0.00 to 50.00 NTU, 50 to 1,000 NTU
Accuracy± 5 % F.S. or ± 0.5 NTU, which ever is greater
Resolution0.01 NTU For 0.00 to 49.99 NTU
DisplayLCD size : 41 mm x 34 mm
Light sourceLED, 850 nm.
Response TimeLess than 10 seconds.
Data HoldFreeze the display reading.
Memory RecallMaximum & Minimum value.
CircuitCustom one-chip of microprocessor LSI circuit.
Operating TemperatureTemp: 0 to 50 ℃, Humi: Less than 85% R.H.
StandardsMeet ISO 7027
Power offAuto shut off saves battery life, or manual off by push button
Sampling TimeApprox. 1 second
Power SupplyDC 1.5 V battery ( UM4, AAA ) x 6 PCs, or equivalent
Detecting PrinciplePhoto diode
AccessoriesClean cloth, Clean solution ( Distill water ), Empty testing bottle, Hard carrying case, CA-08, Testing bottle with 0 NTU standard solution, Testing bottle with 100 NTU standard solution
Optional AccessoriesEmpty testing bottle, 0601, Testing bottle with 0 NTU standard solution, TU-0NTU, Testing bottle with 100 NTU standard solution,TU-100NTU
Dimension6.1 x 3.0 x 2.4 inch
Weight320 Grams