It enables the integration of sophisticated counting and fraud detection features, allowing third-party systems with a universal interface to acquire meter consumption data.
By using an inductive target on the meter, magnetic fraud is eliminated and the application is rendered insensitive to pipe vibrations.
The post B-meters IWM-PL4 Electronic pulse emitter module WDE-K50 appeared first on Adex.
]]>The post B-meters IWM-PL4 Electronic pulse emitter module WDE-K50 appeared first on Adex.
]]>It is simple to install and set, and in addition to providing data on current consumption, it enables the detection of potential water leaks downstream of the meter, prolonged operation at maximum flow rate (Q4), and many sorts of attempted meter fraud.
The application is immune to the vibrations of the pipes thanks to the employment of an inductive target in the meter dial, which also eliminates the potential of magnetic fraud.
The post B-meters IWM-MB3 Wired M-BUS module GMDM-I, GMB-I, GMB-RP-I and CPR-M3-I appeared first on Adex.
]]>The post B-meters IWM-MB3 Wired M-BUS module GMDM-I, GMB-I, GMB-RP-I and CPR-M3-I appeared first on Adex.
]]>It is simple to install and set, and in addition to providing data on current consumption, it enables the detection of potential water leaks downstream of the meter, prolonged operation at maximum flow rate (Q4), and many sorts of attempted meter fraud.
The application is immune to the vibrations of the pipes thanks to the employment of an inductive target in the meter dial, which also eliminates the potential of magnetic fraud.
The post B-Meters IWM-MB4 Wired M-BUS module WDE-K50 appeared first on Adex.
]]>The post B-Meters IWM-MB4 Wired M-BUS module WDE-K50 appeared first on Adex.
]]>The consumption statistics received by each device may be viewed and downloaded using a free B METERS app that can be downloaded from the Google Play Store.
Data that is received can be quickly saved locally or emailed.
The post B-meters RFM-RBT Wireless M-BUS receiver for Smartphones appeared first on Adex.
]]>The post B-meters RFM-RBT Wireless M-BUS receiver for Smartphones appeared first on Adex.
]]>In addition to current consumption and a history of up to 12 previous months, it detects several sorts of attempted meter fraud, prolonged operation at maximum flow rate (Q4), and the presence of a probable water leak downstream of the meter.
The post B-Meters IWM-TX4 Wireless M-BUS radio module WDE-K50 appeared first on Adex.
]]>Magnetic counter tampering and removal are noted and broadcast via radio to the receiving system.
An additional register that enables the calculation of the amount of water passed in reverse keeps track of the existence of reverse flow. If a timely update is desired, the loss function can be monitored at the time of reading or by the AMR system.
- The module can be used for meters deployed in challenging environments thanks to IP68 protection*.
- NFC connectivity enables programming and commissioning of the device using a straightforward smartphone app.
The post B-Meters IWM-TX4 Wireless M-BUS radio module WDE-K50 appeared first on Adex.
]]>In addition to providing data on recent consumption and a history of up to 12 months, it also enables the detection of potential water leaks downstream of the meter, prolonged operation at maximum flow rate (Q4), and various sorts of attempted meter fraud.
The post B-meters IWM-TX3 Wireless M-BUS radio module GMDM-I, GMB-I, GMB-RP-I and CPR-M3-I appeared first on Adex.
]]>and the NFC IWM Config APP freely downloadable from GOOGLE PLAY
* In optimal signal transmission conditions
** The battery life strongly depends on the working time window, set during the configuration process, and on the environmental conditions
The post B-meters IWM-TX3 Wireless M-BUS radio module GMDM-I, GMB-I, GMB-RP-I and CPR-M3-I appeared first on Adex.
]]>Maximum measurement precision, no maintenance requirements, consistent operation over time, and flexibility in installation are all made possible by the absence of internal moving parts in the meter.
The interior lining of the passage tube, either PTFE or EBONITE, permits the management of a wide variety of liquids, including chemically hostile liquids, and the precision of the measurement is not conditioned by the presence of debris and deposits in the measured fluid. GSM/GPRS interface is offered for remote reading.
Available in a different version (MAG-S version) with a cable-connected converter.
The post B-meters MAG-C Electromagnetic flow meter appeared first on Adex.
]]>MAG-S PTFE -40°C /+130°C EBANITE -40°C/+80°C
Stainless steel AISI 304
Carbon steel
MODBUS RTU RS485 (optional: Hart protocol)
IrDA for PC connection, MODBUS on RS485, (GSM/ GPRS)
The post B-meters MAG-C Electromagnetic flow meter appeared first on Adex.
]]>Suitable for monitoring murky water with solid sediments present.
The post B-meters TAN-X5 Tangential irrigation water meter appeared first on Adex.
]]>(inch)
(2″)
(2″1/2)
(3″)
(4″)
(5″)
(6″)
(8″)
±2
±5%
The post B-meters TAN-X5 Tangential irrigation water meter appeared first on Adex.
]]>Available for both cold water up to 50°C and hot water up to 90°C in diameters DN15 - 1/2" and DN20 3/4".
The post B-meters CPR-RP Single jet semi-dry dial meter appeared first on Adex.
]]>(inch)
The post B-meters CPR-RP Single jet semi-dry dial meter appeared first on Adex.
]]>Produced in cold and hot water versions with sizes DN15 and DN20 mm (1/2′′- 3/4′′).
Using inductive pre-equipment, data transmission modules for M-BUS wired and wireless, non-magnetic pulse output, and LoRa can be installed.
The post B-meters CPR-M3-I Single jet, wet dial, direct reading with an anti-fraud ring appeared first on Adex.
]]>(inch)
The post B-meters CPR-M3-I Single jet, wet dial, direct reading with an anti-fraud ring appeared first on Adex.
]]>Maximum measurement precision, zero maintenance requirements, and ongoing operation are all guaranteed by the absence of internal moving parts.
Because debris and deposits do not impact the accuracy of a fluid measurement made with ultrasonic technology, the meter can be installed in any location, whether the flow is ascending or descending.
It can be used in conjunction with the HYDROSPLIT-M3 thermal energy calculator to meet EN 1434 requirements.
The post B-meters HYDROSONIS-UP – Ultrasonic flow sensor appeared first on Adex.
]]>(inch)
(1”)
(1”)
(2”)
(2”1/2)
(3”)
(4”)
The post B-meters HYDROSONIS-UP – Ultrasonic flow sensor appeared first on Adex.
]]>High accuracy, mounting in any installation position, up to R500 (Q3/Q1).
Wireless integrated transmission modules for M-BUS or LoRa.
The post B-meters Hydrosonic-M1 Ultrasonic smart meter appeared first on Adex.
]]>(in)
(1/2″)
(3/4”)
(1”)
(1″1/4”)
(1″1/2”)
The post B-meters Hydrosonic-M1 Ultrasonic smart meter appeared first on Adex.
]]>